By: 30 August 2019
Tailor-made prosthetic liners could help more amputees walk again

Researchers at the University of Bath have developed a new way of designing and manufacturing bespoke prosthetic liners, in less than a day

This potentially life-changing project is combining advances in computer science with an innovative manufacturing process to create affordable new personalised prosthetic liners for lower limb amputees.

There are more than 45,000 people in England alone who rely on prosthetic limbs, with more than 5,000 people each year having new lower-limb amputations. For these individuals, the interface between their residual limb (the amputation site) and their artificial limb is of critical importance for maintaining healthy, active lives, and a good fit could make the difference in whether or not they walk again.

Following an amputation, a person’s residual limb constantly changes in shape and size during the healing process, which can last between 12-18 months. This variation can result in the liner fitting poorly, leading to tissue damage, causing pain and discomfort for amputees. This is exacerbated by patient activity levels and environmental conditions such as hot weather. This discomfort can lead to patients abandoning their prosthesis and rehabilitation regime, instead being forced to rely on a wheelchair.

This project, drawing on the expertise of a multidisciplinary team of researchers from the University of Bath’s Department of Mechanical Engineering, Department for Health and Centre for the Analysis of Motion, Entertainment Research and Applications (CAMERA), is a new approach to providing the liners which fit inside the prosthetic socket that attaches to the artificial leg.

Amputees must currently return to their NHS prosthetist every time their limb changes size for their socket to be replaced or adjusted; many times in the first year following amputation. By providing a series of personalised liners of different sizes, that all fit within the same prosthetic socket, the frequency of these visits can be reduced, improving patient wellbeing and saving the NHS time and money.

Using a state-of-the-art scanner, which quickly captures 3D shape, the research team precisely scans an amputee’s residuum. The scanned data is then used to create a full digital model of the residuum, which is subsequently used to design the personalised liner. The liner is then manufactured using a cryogenic machining technique, negating the need for complex and time-consuming moulds.

At Bath, the researchers are using a soft polymer neoprene-like material – similar to that used in wetsuits – for the liner, which is more comfortable than the silicon liners used by the NHS. The entire process takes less than a day from scanning right through to the physical liner being fitted.

Case study: John Roberts

The Bath researchers are currently trialling this approach with an amputee volunteer John Roberts. He was born with one leg shorter than the other, but despite multiple operations, he suffered years o